Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Infect Control Hosp Epidemiol ; : 1-5, 2023 Mar 13.
Article in English | MEDLINE | ID: covidwho-2265207

ABSTRACT

OBJECTIVE: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) hospital outbreaks have been common and devastating during the coronavirus disease 2019 (COVID-19) pandemic. Understanding SARS-CoV-2 transmission in these environments is critical for preventing and managing outbreaks. DESIGN: Outbreak investigation through epidemiological mapping and whole-genome sequencing phylogeny. SETTING: Hospital in-patient medical unit outbreak in Toronto, Canada, from November 2020 to January 2021. PARTICIPANTS: The outbreak involved 8 patients and 10 staff and was associated with 3 patient deaths. RESULTS: Patients being cared for in geriatric chairs at the nursing station were at high risk for both acquiring and transmitting SARS-CoV-2 to other patients and staff. Furthermore, given the informal nature of these transmissions, they were not initially recognized, which led to further transmission and missing the opportunity for preventative COVID-19 therapies. CONCLUSIONS: During outbreak prevention and management, the risk of informal patient care settings, such as geriatric chairs, should be considered. During high-risk periods or during outbreaks, efforts should be made to care for patients in their rooms when possible.

2.
Vaccine ; 40(33): 4827-4834, 2022 08 05.
Article in English | MEDLINE | ID: covidwho-1907858

ABSTRACT

BACKGROUND: The mRNA COVID vaccines are only licensed for intramuscular injection but it is unclear whether successful intramuscular administration is required for immunogenicity. METHODS: In this observational study, eligible adults receiving their first ComirnatyTM/BNT162b2 dose had their skin to deltoid muscle distance (SDMD) measured by ultrasound. The relationship between SDMD and height, weight, body mass index, and arm circumference was assessed. Three needle length groups were identified: 'clearly sufficient' (needle exceeding SDMD by >5 mm), 'probably sufficient' (needle exceeding SDMD by ≤ 5 mm), and 'insufficient' (needle length ≤ SDMD). Baseline and follow-up finger prick blood samples were collected and the primary outcome variable was mean spike antibody levels in the three needle length groups. RESULTS: Participants (n = 402) had a mean age of 34.7 years, BMI 29.1 kg/m2, arm circumference 37.5 cm, and SDMD 13.3 mm. The SDMD was >25 mm in 23/402 (5.7%) and >20 mm in 61/402 (15.2%) participants. Both arm circumference (≥40 cm) and BMI (≥33 kg/m2) were able to identify those with a SDMD of >25 mm, the length of a standard injection needle, with a sensitivity of 100% and specificities of 71.2 and 79.9%, respectively. Of 249/402 (62%) participants with paired blood samples, there was no significant difference in spike antibody titres between needle length groups. The mean (SD) spike BAU/mL was 464.5 (677.1) in 'clearly sufficient needle length' (n = 217) compared with 506.4 (265.1) in 'probably sufficient' (n = 21, p = 0.09), and 489.4 (452.3) in 'insufficient needle length' (n = 11, p = 0.65). CONCLUSIONS: A 25 mm needle length is likely to be inadequate to ensure vaccine deposition within the deltoid muscle in a small proportion of adults. Vaccine-induced spike antibody titres were comparable in those vaccinated with a needle of sufficient versus insufficient length suggesting deltoid muscle deposition may not be required for an adequate antibody response to mRNA vaccines.


Subject(s)
COVID-19 , Vaccines , Adult , Antibodies, Viral , BNT162 Vaccine , COVID-19 Vaccines , Deltoid Muscle , Humans , Immunogenicity, Vaccine , RNA, Messenger
3.
Mucosal Immunol ; 15(5): 799-808, 2022 05.
Article in English | MEDLINE | ID: covidwho-1805590

ABSTRACT

Although SARS-CoV-2 infects the upper respiratory tract, we know little about the amount, type, and kinetics of antibodies (Ab) generated in the oral cavity in response to COVID-19 vaccination. We collected serum and saliva samples from participants receiving two doses of mRNA COVID-19 vaccines and measured the level of anti-SARS-CoV-2 Ab. We detected anti-Spike and anti-Receptor Binding Domain (RBD) IgG and IgA, as well as anti-Spike/RBD associated secretory component in the saliva of most participants after dose 1. Administration of a second dose of mRNA boosted the IgG but not the IgA response, with only 30% of participants remaining positive for IgA at this timepoint. At 6 months post-dose 2, these participants exhibited diminished anti-Spike/RBD IgG levels, although secretory component-associated anti-Spike Ab were more stable. Examining two prospective cohorts we found that participants who experienced breakthrough infections with SARS-CoV-2 variants had lower levels of vaccine-induced serum anti-Spike/RBD IgA at 2-4 weeks post-dose 2 compared to participants who did not experience an infection, whereas IgG levels were comparable between groups. These data suggest that COVID-19 vaccines that elicit a durable IgA response may have utility in preventing infection. Our study finds that a local secretory component-associated IgA response is induced by COVID-19 mRNA vaccination that persists in some, but not all participants. The serum and saliva IgA response modestly correlate at 2-4 weeks post-dose 2. Of note, levels of anti-Spike serum IgA (but not IgG) at this timepoint are lower in participants who subsequently become infected with SARS-CoV-2. As new surges of SARS-CoV-2 variants arise, developing COVID-19 booster shots that provoke high levels of IgA has the potential to reduce person-to-person transmission.


Subject(s)
COVID-19 , Viral Vaccines , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines , Humans , Prospective Studies , RNA, Messenger/genetics , SARS-CoV-2 , Secretory Component , Vaccination
4.
Clin Transl Immunology ; 11(3): e1380, 2022.
Article in English | MEDLINE | ID: covidwho-1750347

ABSTRACT

Objectives: Antibody testing against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been instrumental in detecting previous exposures and analyzing vaccine-elicited immune responses. Here, we describe a scalable solution to detect and quantify SARS-CoV-2 antibodies, discriminate between natural infection- and vaccination-induced responses, and assess antibody-mediated inhibition of the spike-angiotensin converting enzyme 2 (ACE2) interaction. Methods: We developed methods and reagents to detect SARS-CoV-2 antibodies by enzyme-linked immunosorbent assay (ELISA). The main assays focus on the parallel detection of immunoglobulin (Ig)Gs against the spike trimer, its receptor binding domain (RBD) and nucleocapsid (N). We automated a surrogate neutralisation (sn)ELISA that measures inhibition of ACE2-spike or -RBD interactions by antibodies. The assays were calibrated to a World Health Organization reference standard. Results: Our single-point IgG-based ELISAs accurately distinguished non-infected and infected individuals. For seroprevalence assessment (in a non-vaccinated cohort), classifying a sample as positive if antibodies were detected for ≥ 2 of the 3 antigens provided the highest specificity. In vaccinated cohorts, increases in anti-spike and -RBD (but not -N) antibodies are observed. We present detailed protocols for serum/plasma or dried blood spots analysis performed manually and on automated platforms. The snELISA can be performed automatically at single points, increasing its scalability. Conclusions: Measuring antibodies to three viral antigens and identify neutralising antibodies capable of disrupting spike-ACE2 interactions in high-throughput enables large-scale analyses of humoral immune responses to SARS-CoV-2 infection and vaccination. The reagents are available to enable scaling up of standardised serological assays, permitting inter-laboratory data comparison and aggregation.

5.
J Infect Dis ; 225(5): 768-776, 2022 03 02.
Article in English | MEDLINE | ID: covidwho-1722480

ABSTRACT

BACKGROUND: We determined the burden of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in air and on surfaces in rooms of patients hospitalized with coronavirus disease 2019 (COVID-19) and investigated patient characteristics associated with SARS-CoV-2 environmental contamination. METHODS: Nasopharyngeal swabs, surface, and air samples were collected from the rooms of 78 inpatients with COVID-19 at 6 acute care hospitals in Toronto from March to May 2020. Samples were tested for SARS-CoV-2 ribonucleic acid (RNA), cultured to determine potential infectivity, and whole viral genomes were sequenced. Association between patient factors and detection of SARS-CoV-2 RNA in surface samples were investigated. RESULTS: Severe acute respiratory syndrome coronavirus 2 RNA was detected from surfaces (125 of 474 samples; 42 of 78 patients) and air (3 of 146 samples; 3 of 45 patients); 17% (6 of 36) of surface samples from 3 patients yielded viable virus. Viral sequences from nasopharyngeal and surface samples clustered by patient. Multivariable analysis indicated hypoxia at admission, polymerase chain reaction-positive nasopharyngeal swab (cycle threshold of ≤30) on or after surface sampling date, higher Charlson comorbidity score, and shorter time from onset of illness to sampling date were significantly associated with detection of SARS-CoV-2 RNA in surface samples. CONCLUSIONS: The infrequent recovery of infectious SARS-CoV-2 virus from the environment suggests that the risk to healthcare workers from air and near-patient surfaces in acute care hospital wards is likely limited.


Subject(s)
COVID-19 , Nasopharynx/virology , Respiratory Aerosols and Droplets , SARS-CoV-2/isolation & purification , Adult , Aged , Air Microbiology , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19/transmission , COVID-19 Nucleic Acid Testing , Canada/epidemiology , Environmental Exposure , Health Personnel , Humans , Inpatients , Middle Aged , Pandemics/prevention & control , SARS-CoV-2/genetics
6.
Clin Infect Dis ; 72(6): 1064-1066, 2021 03 15.
Article in English | MEDLINE | ID: covidwho-1132452

ABSTRACT

We enrolled 91 consecutive inpatients with COVID-19 at 6 hospitals in Toronto, Canada, and tested 1 nasopharyngeal swab/saliva sample pair from each patient using real-time RT-PCR for severe acute respiratory syndrome coronavirus 2. Sensitivity was 89% for nasopharyngeal swabs and 72% for saliva (P = .02). Difference in sensitivity was greatest for sample pairs collected later in illness.


Subject(s)
COVID-19 , SARS-CoV-2 , Canada , Humans , Nasopharynx , Real-Time Polymerase Chain Reaction , Saliva
7.
Infect Control Hosp Epidemiol ; 42(8): 1001-1003, 2021 08.
Article in English | MEDLINE | ID: covidwho-977236

ABSTRACT

To compare sensitivity of specimens for COVID-19 diagnosis, we tested 151 nasopharyngeal/midturbinate swab pairs from 117 COVID-19 inpatients using reverse-transcriptase polymerase chain reaction (RT-PCR). Sensitivity was 94% for nasopharyngeal and 75% for midturbinate swabs (P = .0001). In 88 nasopharyngeal/midturbinate pairs with matched saliva, sensitivity was 86% for nasopharyngeal swabs and 88% for combined midturbinate swabs/saliva.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Humans , Nasopharynx , Saliva , Specimen Handling
8.
Sci Immunol ; 5(52)2020 10 08.
Article in English | MEDLINE | ID: covidwho-842548

ABSTRACT

While the antibody response to SARS-CoV-2 has been extensively studied in blood, relatively little is known about the antibody response in saliva and its relationship to systemic antibody levels. Here, we profiled by enzyme-linked immunosorbent assays (ELISAs) IgG, IgA and IgM responses to the SARS-CoV-2 spike protein (full length trimer) and its receptor-binding domain (RBD) in serum and saliva of acute and convalescent patients with laboratory-diagnosed COVID-19 ranging from 3-115 days post-symptom onset (PSO), compared to negative controls. Anti-SARS-CoV-2 antibody responses were readily detected in serum and saliva, with peak IgG levels attained by 16-30 days PSO. Longitudinal analysis revealed that anti-SARS-CoV-2 IgA and IgM antibodies rapidly decayed, while IgG antibodies remained relatively stable up to 105 days PSO in both biofluids. Lastly, IgG, IgM and to a lesser extent IgA responses to spike and RBD in the serum positively correlated with matched saliva samples. This study confirms that serum and saliva IgG antibodies to SARS-CoV-2 are maintained in the majority of COVID-19 patients for at least 3 months PSO. IgG responses in saliva may serve as a surrogate measure of systemic immunity to SARS-CoV-2 based on their correlation with serum IgG responses.


Subject(s)
Antibodies, Viral/blood , Antigens, Viral/immunology , Betacoronavirus/immunology , Coronavirus Infections/immunology , Pneumonia, Viral/immunology , Saliva/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , COVID-19 , Coronavirus Infections/virology , Cross-Sectional Studies , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunoglobulin A/blood , Immunoglobulin A/immunology , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Longitudinal Studies , Male , Middle Aged , Pandemics , Pneumonia, Viral/virology , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL